Load image into Gallery viewer, INOVA DE20, DV20 Medical Grade HEPA Air Purifier, White, Front
Load image into Gallery viewer, INOVA DE20 Air Purifier Black
Load image into Gallery viewer, A rear view of an INOVA DE20 Air Purifier.
Load image into Gallery viewer, INOVA DE20, DV20 Medical Grade HEPA Air Purifier, White, Front
Load image into Gallery viewer, An example of an INOVA DE20 air purifier digital control panel.
Load image into Gallery viewer, A cutaway image showing the prefilter HEPA filter and activated carbon filter inside an INOVA DE20 Air Purifier.

INOVA-DE20 Air Purifier

Regular price $ 1,895.00
Sale price $ 1,895.00 Regular price
Sale Please contact us for delivery pricing.
Unit price
/per 
Color:
White
Black
Out of stock
Payment Methods
This is a pre order item. We will ship it when it comes in stock.

4 Year Warranty

1,076 Square Foot Coverage

610m3/hour clean air delivery

Effective in areas up to 1,076 ft2. The INOVA-DE20 Air Purifier includes precise digital fan control, a 13lb heavy-duty activated carbon filter, and real-time filter monitoring.                                                         

The INOVA-DE20 Air Purifier offers an unmatched level of air purification with the largest H13 medical-grade HEPA filter available in any Australian residential air purifier and a final stage 13lb activated-carbon filter for applications requiring heavy-duty chemical & odor removal. 

The INOVA-DE20 Air Purifier also provides precise digital controls for the user's convenience with 20 digital speeds. Filter life is continually monitored and displayed so you can easily see when filters need replacement.

Actively Removes

  • Bacteria & Viruses
  • Dust, Pollens, and Allergens
  • Mold Spores and Mycotoxins
  • Volatile Organic Compounds (VOC’s)
  • Smoke, Odors, Chemicals and Road Pollution
    • Technostat® high-efficiency pre-filter. 
    • High-capacity cylindrical H13-certified medical-grade HEPA filter with 6.4 square metre surface area and metal casing.
    • 6kg Activated Carbon filter for applications requiring heavy-duty smoke, chemical & odour removal.
    • 100% Airtight filter seals
    • Precise digital control of fan speed
    • Realtime filter life monitoring
    • Preset night and express clean modes
    • High-Flow™ air diffuser with silencer for ultra-quiet operation on low fan speeds
    • Plastic-free, chemical-free aluminium powder-coated construction allows for easy wipe-down and disinfection of external surfaces with any ethanol-based alcohol cleaning agent.
    • EC Fan offers up to 70% energy savings compared to typical AC fans
    • Portability, easily moved from room to room on wheels
    • 100% Ozone free.
    • Australian-made, ensuring quick and reliable support and filter replenishment.
    • Each system is individually certified using a calibrated, Met One, ISO-compliant laser particle counter to meet or exceed the stated efficiency.

    Airflow

    Air delivery up to 610m3/hour.
    Recommended coverage area 20-100m2

    Dimensions

    W:15.4in x D:15.4in x H:25.6in.

    Weight

    43lbs

    Country of Manufacture

    United States.

    Construction

    Powder-coated 1mm, 5052 Grade Aluminium.
    All INOVA air purifier systems are 100% Ozone free.

    Power consumption

    6-125 Watts.

    Motor type

    EC Centrifugal Fan, designed for continuous 24-hour operation.
    Uses 70% less power than typical AC fans.

    Speed control

    20-speed selectable with digital-variable control.

    Sound rating

    34-60 dBA
    Airflow noise only. High-quality, near-silent German-made fan.

    Pre-Filter

    Technostat® electrostatically charged high-efficiency Pre-filter.

    Filter life: Up to 6 months of continuous use**

    HEPA Filter

    H13 Medical-grade. 6.4m² surface area.

    Filter life: 3 - 5 years of continuous use**

    Activated Carbon Filter

    6kg activated carbon filter.

    Filter life: 1 - 3 years of continuous use**

    Warranty

    5 years (parts and labour)***

    * Tested by LMS Technologies Inc (EN1822)

    ** Filter life will vary depending on dust & chemical concentrations present. As operating conditions vary based on levels of dust, chemicals & odours present, and system proximity to major pollution sources.

    *** INOVA does not warranty consumable filter life.



     

    PDF Download INOVA-DE20 User Manual 5.4 Mb

     

    Contents

    1. Important Safety Instructions
    2. Introducing your INOVA system
    3. How your INOVA system works
    4. Positioning your INOVA system
    5. System operation
    6. Accessing the filters
    7. Recommended filter replacement intervals
    8. When to replace the filters.
    9. The digital controller

    1. Important safety instructions

    To reduce the risk of fire, electric shock, or injury

    1. Do not detach motor outlet module until the system has been switched off.
    2. Disconnect power, or unplug, before cleaning, performing any maintenance or replacing a filter.
    3. Use caution when moving the air purifier to avoid injury. We advise removing the filters prior to lifting or transporting the system.
    4. Do not operate unless all components are fully assembled, securely latched and in the upright position. Failure to do so may result in serious injury.
    5. Leave a distance of at least 150mm between the appliance and the nearest wall to allow for adequate air circulation.
    6. Always keep the air intake and outlet of the unit unobstructed.
    7. Do not use near water or moisture or the immediate surroundings of a bath, shower, or swimming pool.
    8. Do not immerse the air purifier in water or any other liquid.
    9. Do not let objects or liquids, enter the product.
    10. Do not handle any part of the appliance or plug with wet hands.
    11. Clean only with a dry cloth.
    12. Do not install near any heat sources.
    13. Do not operate this appliance if it has a damaged cord or plug, is not working correctly, or has been dropped.
    14. Do not use this appliance if it has been damaged or submerged in water.
    15. The appliance is not to be used by persons (including children) with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge unless they have been given supervision or instruction.
    16. If the supply cord is damaged, it must be replaced with a new cord. Contact our support team for a replacement.
    17. Keep power cord away from heated surfaces.
    18. Refer all servicing to qualified INOVA service personnel. Servicing is required when the product has been damaged in any way. Do not attempt to service this product yourself. Opening or removing covers may expose you to dangerous voltages or other hazards and may void warranty.
    19. Unplug the air purifier during lightning storms or when unused for long periods.
    20. Do not use this appliance as sole protection against harmful pollutants.
    21. Do not use outdoors.
    22. Keep the appliance away from flammable liquids, vapours, air fresheners and essential oils.
    23. Do not use in explosive or flammable environments.
    24. Use only on solid, horizontal, and stable surfaces.

    2. Introducing your INOVA system

    Inside the DE20 boxes, you will find the INOVA unit consisting of:

    1. INOVA-DE20 System Case/Motor
    2. Filter Base Plate (detachable)
    3. Power Cable (located in base of box)
    4. DE20 Pre-filter (pre-installed)
    5. DE20 HEPA Filter (pre-installed)
    6. DE20 6kg Activated Carbon Filter (supplied in a separate box)

    3. How your INOVA system works

    1. Air is drawn into the system through the sides of the unit.
    2. Air passes through the dust pre-filter.
    3. Air passes through the H13 HEPA filter which removes dust, allergens and sub-micron fine particle matter.
    4. Chemicals and odours are removed from the air in the final stage by the Activated Carbon filter.
    5. The purified air is then returned to the room via the high air-flow diffuser.

    4. Positioning your INOVA system

    There are two main points to consider: where you spend your time and where the main pollutants are.

    The longer you keep your INOVA-DE20 in a single room, the cleaner the air in that room will be. As with a heater or air conditioner, the INOVA air purifier will only be effective if windows are closed during operation.

    Your INOVA works best when it has plenty of unrestricted airflow around it.

    It is also important to make sure the air purifier has easy access to a power outlet as long cords can be a tripping hazard and may result in damage to the unit should it be knocked over.


    5. System operation

    The system has a 20-speed digital controller and uses an energy efficient European EC fan. Power consumption is relative to the selected speed.

    The higher the speed the more times per hour the air in your living space will be cleaned, so it is recommended to run the system at the highest speed you are comfortable with.

    Higher fan speeds will generate higher sound levels. Generally for sleeping, an ideal setting is position 1-2.


    6. Accessing the filters

    1. Disconnect the power cord.
    2. Ensure system is sitting on a flat and even surface.
    3. Pull top of the latches away from the main unit.
    4. Push the latches back towards the main unit
    5. Ensure the latch clasps are clear of catches on the base
    6. Lift casing clear of base to access filters

    7. Recommended filter replacement intervals

    • Pre-Filter (Wrap-around) | 3-6 months
    • H13 HEPA Filter | 3-5 years
    • 6kg Activated Carbon Filter | Maximum 3 years

    * Based on 60% daily usage in environments with average particulate/chemical levels. Operating conditions will vary based on levels of dust, chemicals & odours present, and system proximity to major pollution sources each of which may lower any of the filter lifespans. INOVA does not warranty consumable filter life.


    8. When to replace the filters

    Stage 1: Pre-filter

    The pre-filter is the initial stage of filtration, filtering large dust particles right down to ultra-fine sub-micron particles. It is made from a patented material used in respirators and face masks. On average the pre-filter is designed to last up to 6 months of continuous use. Dust levels in the ambient air will affect how long the pre-filter will last. Pre-filters are white and will turn grey fairly quickly within 1-2 weeks of use, this is nothing to be concerned about and simply means the filter is doing its job. We recommend checking the dust buildup on the pre-filter every 3 months of use. When the dust layer is approximately 2 mm thick the pre-filter should be replaced.

    Stage 2: Medical-grade HEPA filter

    The H13 HEPA filter is designed to last 3 to 5 years under normal use. As with other filters, the environment in which it is used will determine the filter life. The outside of the HEPA filter will change colour and turn dark grey when it needs changing. Generally for the first two years of use the filter will remain white and then gradually get darker in the final months of its life. Please note, the inside of the HEPA filter will always remain white so it is important to check the outside of the filter which is visible when the Pre-filter is being changed.

    Stage 3: Final stage activated carbon filter

    The DE20 6kg activated carbon filter adsorbs chemicals, gases and odours from the air and, depending on the environment, will last up to 3 years. Carbon filters should be changed when they are saturated, this means the filter has entirely filled up with what it has filtered from the air during use. You can tell when a carbon filter needs changing because the air coming out of the air purifier will either be tainted with an odour of what it has adsorbed during use, or the air will simply stop smelling clean or smell stale.

    When changing pre-filters

    It is best to remove the HEPA filter with the pre-filter intact and take outside so no dust is released into the environment when changing. If not practical to do so, you can simply place a large garbage bag over the entire HEPA filter/pre-filter and remove the pre-filter inside the bag.

    If you suffer from dust allergies, we recommend moving the system outside before removing the pre-filter to avoid the possibility of dust being released in your environment. Alternatively, wear a dust mask if performing this operation inside.

    Important: Do not attempt to vacuum the HEPA or Pre-filter as this will damage the fine filter fibres and reduce efficiency. Air intake vents on the sides of the system can be vacuumed including the base plate which sits under the filters.


    9. The Digital Controller

    Connect the power cord supplied to the power cord inlet on the back of the unit, and switch the Main Power On/Off Switch to ON. The system will initiate the startup power cycle and all LEDS will illuminate momentarily.

    InovaSmartTM Digital Controller

    Designed for intuitive operation the digital interface on your InovaAir system continuously keeps track of filter life by monitoring system usage based on hours of use and speed of the fan during operation.

    1. FILTER CHECK
      Filter Life indicator lights will illuminate separately when the “Filter Check” button is pressed and a number will appear in the LED display showing how many month(s) of life each filter has remaining.

      Filter longevity based on 24-hour usage: Pre-filter: 6 months; HEPA Filter: 36 Months; 6kg Activated Carbon Filter: 36 Months.

      Please note. The filter replacement intervals are calculated based on the current fan speed. Running the system at higher fan speeds will result in a reduced replacement interval.

    2. EXPRESS CLEAN
      When pressed this allows the user to preselect maximum speed for a period of between 15-90 minutes, using the fan speed control buttons (4), in 15-minute increments. After the set period elapses the system will resume to the previously set speed.

    3. NIGHT MODE
      Turns off all LED lights to improve sleeping conditions (except night mode LED which is dimmed).

    4. FAN SPEED
      Allows precise control of fan speed, levels 1 through 20, and increases time increments (express clean).

    5. LED DISPLAY
      This functions as the main display for the system numerically, showing: speed, filter life and Express Clean status.

    6. FAN SPEED INDICATOR
      LED bar increases with fan speed as a visual indicator of speed in addition to the numeric display.

    Monitoring filter replacement - Default factory settings

    • Pre-Filter (Wrap-around) - 6 months
    • H13 HEPA Filter - 36 months
    • Activated Carbon Filter - 36 months

     

    FILTER CHECK
    Press “Filter Check” button once and filters PRE-FILTER, HEPA or CARBON illuminate (illustration shows HEPA as an example only) in sequence and display the remaining life of each filter. Filter life is displayed in months based on the current fan speed.

    STANDARD FILTER LIFE RESET
    When the filter light illuminates (illustration shows HEPA as an example only) for the filter you want to replace, press and continuously hold “Filter Check” for 5 seconds, the display screen will start to flash. When the flashing stops, filter life has been reset to factory default above.

    CUSTOMISING FILTER REPLACEMENT INTERVALS
    To increase or decrease filter life to a custom setting, press “Filter Check” button once to select the filter life to customise (illustration shows HEPA as example only).

    Press and hold “Filter Check” button when the filter to be changed is illuminated (NOTE: CONTINUE TO HOLD THROUGHOUT THIS ENTIRE ADJUSTMENT PROCESS). Once initial flashing has stopped use the “Fan Speed” buttons to decrease the filter life in months. When the desired number of months are displayed, continue to hold down “Filter Check” button, the display will flash again for 5 seconds to indicate the new setting has been saved as your preferred default filter life. (To revert to factory defaults see item 2 procedure above) Please note: the custom filter life intervals can only be less than the default values above.

    CUSTOM FAN SPEED FOR NIGHT MODE
    Default night mode is set to speed 5, to set a custom fan speed for “Night Mode,” use the arrows to adjust the fan to the desired number. Then hold the “Night Mode” button for at least 5 seconds. When released the display will show “I II I” to confirm the new set speed.

     

     

    Always operate the system with windows closed.

    Air purifiers are not designed to filter the great outdoors, like an air conditioner or heater leaving a window open will render the system ineffective. The use of evaporative coolers will also reduce effectiveness.

    Operate the system 24/7.

    As dust, allergens, and chemicals are always present in the air, for maximum effectiveness you should operate the system continuously. By switching the system off you are only allowing these contaminants to build up in the interim until it is switched back on. INOVA systems are designed for optimal energy efficiency – so don’t be concerned about power consumption as this will barely be noticeable on an electricity bill.

    Decide where you need clean air the most.

    Typically for allergy and asthma sufferers, use while sleeping will be an important part of how you use your air purifier. If you have a high-capacity system with adequate coverage, it can be moved between living areas during the day and the bedroom at night. Operation for 15-30mins on high speed will dramatically reduce the bulk of airborne particulates when moving into a new room.

    Enclose the area where you are operating the system.

    If you close a bedroom door the system will be much more effective as it will only be filtering the air in one room. If you move to larger areas, if possible, close off surrounding areas to maintain clean air in that space. E7 and E8 models are designed primarily for bedroom use, while the high-capacity E20 and DE20 models are designed to cover large living areas and be moved to bedrooms for nighttime use.

    Operate at the highest speed you are comfortable with.

    All INOVA systems include variable speed controls, and the speed should be varied depending on the room size, the level of air pollutants present and the sensitivity of the individual. The higher the operating speed the more effective the system will be, as the purifier will be filtering the air more times every hour resulting in lower levels of particles and certain chemicals. When operating smaller systems in larger areas, increase the operating speed to enable the system to filter the air more effectively.

    Activated carbon filters.

    While they are highly efficient at removing chemicals and odours, if you have high levels of any chemicals or odours, they will absorb these from the air quickly and the filter life will be reduced. If you want to prolong the life of the activated carbon filter, you should turn the system off while cooking or if there are any heavy transient odours.

    Check your pre-filters regularly for dust build-up.

    We recommend that you check your pre-filter after every three months of operation to visually inspect the level of dust build-up. Pre-filters typically last between 3 to 6 months based on average dust levels in a home environment. If the levels of dust in your home are high due to external factors such as living near a main road, you may need to change your filters more regularly. Change of filter colour alone from white to grey does not indicate the filter needs changing, rather a thick dust layer does. Do not vacuum or wash pre-filters, they are made from very high-efficiency material which is not designed for vacuuming or washing. These actions will damage the pre-filter and reduce the life of the HEPA filter by allowing dirt to pass through.

    Know when to change your main filters.

    The HEPA filter will require replacement when the outside, the side immediately visible underneath the pre-filter, changes colour from white to dark grey – this typically takes some years to occur as long as you have maintained and changed your pre-filter on a regular basis. Activated carbon filters, when saturated with chemicals or odours, will leave the air tainted with an odour. If the air coming out of your purifier develops any sort of noticeable odour, the carbon filter may require replacement.

    Positioning your INOVA system.

    There are two main points to consider: where you spend your time and where the main pollutants are. The longer you keep your INOVA in a single room, the cleaner the air in that room will be. As with a heater or air conditioner, the INOVA purifier will only be effective if windows are closed during operation.

    Your INOVA system works best when it has plenty of unrestricted airflow around it. It is also important to make sure the Air Purifier has easy access to a power outlet as long cords can be a tripping hazard and may result in damage to the unit should it be knocked over.

    Pre-filters changes.

    when changing the pre-filter, it is best to remove the HEPA filter with the pre-filter intact and take it outside so no dust is released in your environment.
    If not practical to do so you can simply place a large garbage bag over the entire HEPA filter/pre-filter and remove the pre-filter inside the bag.

    Features
    • Technostat® high-efficiency pre-filter. 
    • High-capacity cylindrical H13-certified medical-grade HEPA filter with 6.4 square metre surface area and metal casing.
    • 6kg Activated Carbon filter for applications requiring heavy-duty smoke, chemical & odour removal.
    • 100% Airtight filter seals
    • Precise digital control of fan speed
    • Realtime filter life monitoring
    • Preset night and express clean modes
    • High-Flow™ air diffuser with silencer for ultra-quiet operation on low fan speeds
    • Plastic-free, chemical-free aluminium powder-coated construction allows for easy wipe-down and disinfection of external surfaces with any ethanol-based alcohol cleaning agent.
    • EC Fan offers up to 70% energy savings compared to typical AC fans
    • Portability, easily moved from room to room on wheels
    • 100% Ozone free.
    • Australian-made, ensuring quick and reliable support and filter replenishment.
    • Each system is individually certified using a calibrated, Met One, ISO-compliant laser particle counter to meet or exceed the stated efficiency.
    Specifications

    Airflow

    Air delivery up to 610m3/hour.
    Recommended coverage area 20-100m2

    Dimensions

    W:15.4in x D:15.4in x H:25.6in.

    Weight

    43lbs

    Country of Manufacture

    United States.

    Construction

    Powder-coated 1mm, 5052 Grade Aluminium.
    All INOVA air purifier systems are 100% Ozone free.

    Power consumption

    6-125 Watts.

    Motor type

    EC Centrifugal Fan, designed for continuous 24-hour operation.
    Uses 70% less power than typical AC fans.

    Speed control

    20-speed selectable with digital-variable control.

    Sound rating

    34-60 dBA
    Airflow noise only. High-quality, near-silent German-made fan.

    Pre-Filter

    Technostat® electrostatically charged high-efficiency Pre-filter.

    Filter life: Up to 6 months of continuous use**

    HEPA Filter

    H13 Medical-grade. 6.4m² surface area.

    Filter life: 3 - 5 years of continuous use**

    Activated Carbon Filter

    6kg activated carbon filter.

    Filter life: 1 - 3 years of continuous use**

    Warranty

    5 years (parts and labour)***

    * Tested by LMS Technologies Inc (EN1822)

    ** Filter life will vary depending on dust & chemical concentrations present. As operating conditions vary based on levels of dust, chemicals & odours present, and system proximity to major pollution sources.

    *** INOVA does not warranty consumable filter life.



    User Manual

     

    PDF Download INOVA-DE20 User Manual 5.4 Mb

     

    Contents

    1. Important Safety Instructions
    2. Introducing your INOVA system
    3. How your INOVA system works
    4. Positioning your INOVA system
    5. System operation
    6. Accessing the filters
    7. Recommended filter replacement intervals
    8. When to replace the filters.
    9. The digital controller

    1. Important safety instructions

    To reduce the risk of fire, electric shock, or injury

    1. Do not detach motor outlet module until the system has been switched off.
    2. Disconnect power, or unplug, before cleaning, performing any maintenance or replacing a filter.
    3. Use caution when moving the air purifier to avoid injury. We advise removing the filters prior to lifting or transporting the system.
    4. Do not operate unless all components are fully assembled, securely latched and in the upright position. Failure to do so may result in serious injury.
    5. Leave a distance of at least 150mm between the appliance and the nearest wall to allow for adequate air circulation.
    6. Always keep the air intake and outlet of the unit unobstructed.
    7. Do not use near water or moisture or the immediate surroundings of a bath, shower, or swimming pool.
    8. Do not immerse the air purifier in water or any other liquid.
    9. Do not let objects or liquids, enter the product.
    10. Do not handle any part of the appliance or plug with wet hands.
    11. Clean only with a dry cloth.
    12. Do not install near any heat sources.
    13. Do not operate this appliance if it has a damaged cord or plug, is not working correctly, or has been dropped.
    14. Do not use this appliance if it has been damaged or submerged in water.
    15. The appliance is not to be used by persons (including children) with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge unless they have been given supervision or instruction.
    16. If the supply cord is damaged, it must be replaced with a new cord. Contact our support team for a replacement.
    17. Keep power cord away from heated surfaces.
    18. Refer all servicing to qualified INOVA service personnel. Servicing is required when the product has been damaged in any way. Do not attempt to service this product yourself. Opening or removing covers may expose you to dangerous voltages or other hazards and may void warranty.
    19. Unplug the air purifier during lightning storms or when unused for long periods.
    20. Do not use this appliance as sole protection against harmful pollutants.
    21. Do not use outdoors.
    22. Keep the appliance away from flammable liquids, vapours, air fresheners and essential oils.
    23. Do not use in explosive or flammable environments.
    24. Use only on solid, horizontal, and stable surfaces.

    2. Introducing your INOVA system

    Inside the DE20 boxes, you will find the INOVA unit consisting of:

    1. INOVA-DE20 System Case/Motor
    2. Filter Base Plate (detachable)
    3. Power Cable (located in base of box)
    4. DE20 Pre-filter (pre-installed)
    5. DE20 HEPA Filter (pre-installed)
    6. DE20 6kg Activated Carbon Filter (supplied in a separate box)

    3. How your INOVA system works

    1. Air is drawn into the system through the sides of the unit.
    2. Air passes through the dust pre-filter.
    3. Air passes through the H13 HEPA filter which removes dust, allergens and sub-micron fine particle matter.
    4. Chemicals and odours are removed from the air in the final stage by the Activated Carbon filter.
    5. The purified air is then returned to the room via the high air-flow diffuser.

    4. Positioning your INOVA system

    There are two main points to consider: where you spend your time and where the main pollutants are.

    The longer you keep your INOVA-DE20 in a single room, the cleaner the air in that room will be. As with a heater or air conditioner, the INOVA air purifier will only be effective if windows are closed during operation.

    Your INOVA works best when it has plenty of unrestricted airflow around it.

    It is also important to make sure the air purifier has easy access to a power outlet as long cords can be a tripping hazard and may result in damage to the unit should it be knocked over.


    5. System operation

    The system has a 20-speed digital controller and uses an energy efficient European EC fan. Power consumption is relative to the selected speed.

    The higher the speed the more times per hour the air in your living space will be cleaned, so it is recommended to run the system at the highest speed you are comfortable with.

    Higher fan speeds will generate higher sound levels. Generally for sleeping, an ideal setting is position 1-2.


    6. Accessing the filters

    1. Disconnect the power cord.
    2. Ensure system is sitting on a flat and even surface.
    3. Pull top of the latches away from the main unit.
    4. Push the latches back towards the main unit
    5. Ensure the latch clasps are clear of catches on the base
    6. Lift casing clear of base to access filters

    7. Recommended filter replacement intervals

    • Pre-Filter (Wrap-around) | 3-6 months
    • H13 HEPA Filter | 3-5 years
    • 6kg Activated Carbon Filter | Maximum 3 years

    * Based on 60% daily usage in environments with average particulate/chemical levels. Operating conditions will vary based on levels of dust, chemicals & odours present, and system proximity to major pollution sources each of which may lower any of the filter lifespans. INOVA does not warranty consumable filter life.


    8. When to replace the filters

    Stage 1: Pre-filter

    The pre-filter is the initial stage of filtration, filtering large dust particles right down to ultra-fine sub-micron particles. It is made from a patented material used in respirators and face masks. On average the pre-filter is designed to last up to 6 months of continuous use. Dust levels in the ambient air will affect how long the pre-filter will last. Pre-filters are white and will turn grey fairly quickly within 1-2 weeks of use, this is nothing to be concerned about and simply means the filter is doing its job. We recommend checking the dust buildup on the pre-filter every 3 months of use. When the dust layer is approximately 2 mm thick the pre-filter should be replaced.

    Stage 2: Medical-grade HEPA filter

    The H13 HEPA filter is designed to last 3 to 5 years under normal use. As with other filters, the environment in which it is used will determine the filter life. The outside of the HEPA filter will change colour and turn dark grey when it needs changing. Generally for the first two years of use the filter will remain white and then gradually get darker in the final months of its life. Please note, the inside of the HEPA filter will always remain white so it is important to check the outside of the filter which is visible when the Pre-filter is being changed.

    Stage 3: Final stage activated carbon filter

    The DE20 6kg activated carbon filter adsorbs chemicals, gases and odours from the air and, depending on the environment, will last up to 3 years. Carbon filters should be changed when they are saturated, this means the filter has entirely filled up with what it has filtered from the air during use. You can tell when a carbon filter needs changing because the air coming out of the air purifier will either be tainted with an odour of what it has adsorbed during use, or the air will simply stop smelling clean or smell stale.

    When changing pre-filters

    It is best to remove the HEPA filter with the pre-filter intact and take outside so no dust is released into the environment when changing. If not practical to do so, you can simply place a large garbage bag over the entire HEPA filter/pre-filter and remove the pre-filter inside the bag.

    If you suffer from dust allergies, we recommend moving the system outside before removing the pre-filter to avoid the possibility of dust being released in your environment. Alternatively, wear a dust mask if performing this operation inside.

    Important: Do not attempt to vacuum the HEPA or Pre-filter as this will damage the fine filter fibres and reduce efficiency. Air intake vents on the sides of the system can be vacuumed including the base plate which sits under the filters.


    9. The Digital Controller

    Connect the power cord supplied to the power cord inlet on the back of the unit, and switch the Main Power On/Off Switch to ON. The system will initiate the startup power cycle and all LEDS will illuminate momentarily.

    InovaSmartTM Digital Controller

    Designed for intuitive operation the digital interface on your InovaAir system continuously keeps track of filter life by monitoring system usage based on hours of use and speed of the fan during operation.

    1. FILTER CHECK
      Filter Life indicator lights will illuminate separately when the “Filter Check” button is pressed and a number will appear in the LED display showing how many month(s) of life each filter has remaining.

      Filter longevity based on 24-hour usage: Pre-filter: 6 months; HEPA Filter: 36 Months; 6kg Activated Carbon Filter: 36 Months.

      Please note. The filter replacement intervals are calculated based on the current fan speed. Running the system at higher fan speeds will result in a reduced replacement interval.

    2. EXPRESS CLEAN
      When pressed this allows the user to preselect maximum speed for a period of between 15-90 minutes, using the fan speed control buttons (4), in 15-minute increments. After the set period elapses the system will resume to the previously set speed.

    3. NIGHT MODE
      Turns off all LED lights to improve sleeping conditions (except night mode LED which is dimmed).

    4. FAN SPEED
      Allows precise control of fan speed, levels 1 through 20, and increases time increments (express clean).

    5. LED DISPLAY
      This functions as the main display for the system numerically, showing: speed, filter life and Express Clean status.

    6. FAN SPEED INDICATOR
      LED bar increases with fan speed as a visual indicator of speed in addition to the numeric display.

    Monitoring filter replacement - Default factory settings

    • Pre-Filter (Wrap-around) - 6 months
    • H13 HEPA Filter - 36 months
    • Activated Carbon Filter - 36 months

     

    FILTER CHECK
    Press “Filter Check” button once and filters PRE-FILTER, HEPA or CARBON illuminate (illustration shows HEPA as an example only) in sequence and display the remaining life of each filter. Filter life is displayed in months based on the current fan speed.

    STANDARD FILTER LIFE RESET
    When the filter light illuminates (illustration shows HEPA as an example only) for the filter you want to replace, press and continuously hold “Filter Check” for 5 seconds, the display screen will start to flash. When the flashing stops, filter life has been reset to factory default above.

    CUSTOMISING FILTER REPLACEMENT INTERVALS
    To increase or decrease filter life to a custom setting, press “Filter Check” button once to select the filter life to customise (illustration shows HEPA as example only).

    Press and hold “Filter Check” button when the filter to be changed is illuminated (NOTE: CONTINUE TO HOLD THROUGHOUT THIS ENTIRE ADJUSTMENT PROCESS). Once initial flashing has stopped use the “Fan Speed” buttons to decrease the filter life in months. When the desired number of months are displayed, continue to hold down “Filter Check” button, the display will flash again for 5 seconds to indicate the new setting has been saved as your preferred default filter life. (To revert to factory defaults see item 2 procedure above) Please note: the custom filter life intervals can only be less than the default values above.

    CUSTOM FAN SPEED FOR NIGHT MODE
    Default night mode is set to speed 5, to set a custom fan speed for “Night Mode,” use the arrows to adjust the fan to the desired number. Then hold the “Night Mode” button for at least 5 seconds. When released the display will show “I II I” to confirm the new set speed.

     

     

    Operating Tips

    Always operate the system with windows closed.

    Air purifiers are not designed to filter the great outdoors, like an air conditioner or heater leaving a window open will render the system ineffective. The use of evaporative coolers will also reduce effectiveness.

    Operate the system 24/7.

    As dust, allergens, and chemicals are always present in the air, for maximum effectiveness you should operate the system continuously. By switching the system off you are only allowing these contaminants to build up in the interim until it is switched back on. INOVA systems are designed for optimal energy efficiency – so don’t be concerned about power consumption as this will barely be noticeable on an electricity bill.

    Decide where you need clean air the most.

    Typically for allergy and asthma sufferers, use while sleeping will be an important part of how you use your air purifier. If you have a high-capacity system with adequate coverage, it can be moved between living areas during the day and the bedroom at night. Operation for 15-30mins on high speed will dramatically reduce the bulk of airborne particulates when moving into a new room.

    Enclose the area where you are operating the system.

    If you close a bedroom door the system will be much more effective as it will only be filtering the air in one room. If you move to larger areas, if possible, close off surrounding areas to maintain clean air in that space. E7 and E8 models are designed primarily for bedroom use, while the high-capacity E20 and DE20 models are designed to cover large living areas and be moved to bedrooms for nighttime use.

    Operate at the highest speed you are comfortable with.

    All INOVA systems include variable speed controls, and the speed should be varied depending on the room size, the level of air pollutants present and the sensitivity of the individual. The higher the operating speed the more effective the system will be, as the purifier will be filtering the air more times every hour resulting in lower levels of particles and certain chemicals. When operating smaller systems in larger areas, increase the operating speed to enable the system to filter the air more effectively.

    Activated carbon filters.

    While they are highly efficient at removing chemicals and odours, if you have high levels of any chemicals or odours, they will absorb these from the air quickly and the filter life will be reduced. If you want to prolong the life of the activated carbon filter, you should turn the system off while cooking or if there are any heavy transient odours.

    Check your pre-filters regularly for dust build-up.

    We recommend that you check your pre-filter after every three months of operation to visually inspect the level of dust build-up. Pre-filters typically last between 3 to 6 months based on average dust levels in a home environment. If the levels of dust in your home are high due to external factors such as living near a main road, you may need to change your filters more regularly. Change of filter colour alone from white to grey does not indicate the filter needs changing, rather a thick dust layer does. Do not vacuum or wash pre-filters, they are made from very high-efficiency material which is not designed for vacuuming or washing. These actions will damage the pre-filter and reduce the life of the HEPA filter by allowing dirt to pass through.

    Know when to change your main filters.

    The HEPA filter will require replacement when the outside, the side immediately visible underneath the pre-filter, changes colour from white to dark grey – this typically takes some years to occur as long as you have maintained and changed your pre-filter on a regular basis. Activated carbon filters, when saturated with chemicals or odours, will leave the air tainted with an odour. If the air coming out of your purifier develops any sort of noticeable odour, the carbon filter may require replacement.

    Positioning your INOVA system.

    There are two main points to consider: where you spend your time and where the main pollutants are. The longer you keep your INOVA in a single room, the cleaner the air in that room will be. As with a heater or air conditioner, the INOVA purifier will only be effective if windows are closed during operation.

    Your INOVA system works best when it has plenty of unrestricted airflow around it. It is also important to make sure the Air Purifier has easy access to a power outlet as long cords can be a tripping hazard and may result in damage to the unit should it be knocked over.

    Pre-filters changes.

    when changing the pre-filter, it is best to remove the HEPA filter with the pre-filter intact and take it outside so no dust is released in your environment.
    If not practical to do so you can simply place a large garbage bag over the entire HEPA filter/pre-filter and remove the pre-filter inside the bag.

    High Airflow Air Purifiers

    The Inova® Difference

    The INOVA-DE20 features high-efficiency 3-stage filtration.

    All three filters are included with the initial system purchase.

    Medical-Grade Filters
    • Medical-Grade Filters

    • We only use H13 medical-grade HEPA paper in our filters rather than the synthetic polypropylene that you will find in most consumer grade air purifiers.
    Longer Filter Life
    Longer Filter Life
    • Longer Filter Life

    • INOVA HEPA filters last up to 10x longer than other brands.

    Replacement Filters

    Regular price $ 100.00
    Sale price $ 100.00
    Regular price
    Unit price
    per 
    The electrostatically charged first-stage pre-filter is designed to remove ambient fine dust particles and up to 99% of bacteria & viruses from the air. For use in the following models E20 Plu...
    Regular price $ 490.00
    Sale price $ 490.00
    Regular price
    Unit price
    per 
    This is a complete filter set for your E20 or DE20 system, including a pre-filter, H13 HEPA filter, and 6kg activated carbon filter.  Save $50 compared to buying all three filters separately.   Tec...
    Regular price $ 295.00
    Sale price $ 295.00
    Regular price
    Unit price
    per 
    Filter Life 3 - 5 years continuous use** The HEPA filter removes viruses, bacteria, mold spores, allergens, pollen, and dust mites before passing the air on to the third-stage filter. The E20/DE20...
    Regular price $ 195.00
    Sale price $ 195.00
    Regular price
    Unit price
    per 
    A 6kg activated carbon final stage filter, manufactured with a heavy-duty steel casing and airtight seals. Designed to remove chemical pollutants, volatile organic compounds (VOCs), smoke, road pol...
    Regular price $ 50.00
    Sale price $ 50.00
    Regular price
    Unit price
    per 
    The electrostatically charged first-stage pre-filter is designed to remove ambient fine dust particles and up to 99% of bacteria & viruses from the air. For use in the following models E20 Plu...